NFP Pilot Clamp - Complete Kit

SKU
FP200
The NFP Pilot Clamp® complete kit cuts perfect holes in cylindrical pipe. This device can cut up to 2-inch (5.08 cm) holes in up to 4-inch (10.16 cm) diameter pipe. Features jaws that lock around pipe using Vise Grip handles & multiple bubble levels for precision cuts.
$599.95
  • Buy 2 for $581.95 each and save 3%
  • Buy 10 for $569.95 each and save 5%
  • Buy 50 for $539.96 each and save 10%
Part Number Kit Includes Shipping
FP200 PILOT CLAMP® with levels
Six (6) interchangeable hole saw guides  (1", 1-3/16" 1-1/4", 1-1/2", 1-3/4", and 2")
Six (6) Lenox® Bi-Metal hole saws
Two (2) Lenox® arbors
Pilot bit
Hole size chart (see image)
Carrying case

Currently in stock in limited quantity.

Call 888-361-6662 to order over the phone!

When In Stock: Ships within 24 Hours

If out of stock: Call 888-361-6662 to reserve yours today!

 

Product Description

The NFP Pilot Clamp® complete kit, available online from QRFS, is the ideal solution for cutting perfect holes in a cylindrical pipe on the job site. This patent-pending device can cut up to 2-inch (5.08 cm) holes in up to 4-inch (10.16 cm) diameter pipe.

The NFP Pilot Clamp features jaws that lock around pipe using Vise Grip handles. The Pilot Clamp's head has multiple bubble levels to ensure consistent, level holes each and every time. With its innovative design, you can drill wobble-free clean holes either vertically or horizontally in tight, cramped spaces such as behind walls or in between trusses using the regular, cordless, or right-angle drill you already own. It even works to expand existing holes, such as when you need to replace a waterflow detector.

With the NFP Pilot Clamp, you can save both time and money by avoiding expensive in-shop fabrication or replacing existing pipes with a too-small diameter hole.

Ideal for cutting holes to install:

  • Mechanical Tees
  • Crosses
  • Welded outlets
  • Threaded outlets
  • Detection devices (flow or pressure switches)

Comes standard with:

  • Pilot Clamp with levels
  • Six (6) interchangeable hole saw guides (sized for fire protection use 1", 1-3/16" 1-1/4", 1-1/2", 1-3/4", and 2")
  • Six (6) Lenox® Bi-Metal hole saws
  • Two (2) Lenox® arbors
  • Pilot bit
  • Hole size chart (see image)
  • Carrying case

Get to Know The NFP Pilot Clamp

At QRFS, we stock Pilot Clamps and ALL REPLACEMENT PARTS. Usually ships same day!

Not sure if this is the right tool for you? Check out these helpful resources:

What is a Pilot Clamp?

Use a Pilot Clamp in 6 Easy Steps

Write Your Own Review
You're reviewing:NFP Pilot Clamp - Complete Kit
Your Rating